OEM Installation
The effectiveness of the ozone generator is dependent on the design delivery
system per each manufacturer. It is the responsibility of the installer to follow the
installation procedures set forth by the manufacturer. Failure to do so will void the
warranty. Diagram 2 shows the basic layout recommended for the installation of
Balboa’s Ozone Generator.
1. Turn off all power.
2. Loop the hose into a “Hartford Loop” and have the upper part of the loops
positioned above the water line level as shown. Failure to do so could result
in water intrusion, which is not covered by the warranty. Attach the hose to the
ozone injector tting on the spa plumbing. Install the check valve so that the
arrow points in the direction of air ow from the generator to the ozone injector
(Diagram 2).
Note: If you do not properly install the check valve, the air ow will be blocked
from going into the spa/pool and will not perform the ozonation process.
3. Power up the system and briey run the ltration pump. Place your nger over
the end of the hose near the check valve. You should feel a slight suction. If not,
check for hose kinks, hose obstructions, and that the check valve is in the proper
direction. When suction is obtained, attach the hose from the generator to the
barbed output of the ozone generator.
4. Turn off the control system and hook the power cable to the control system
marked for Ozone. (Follow the system’s wiring diagram for the proper location.)
5. Turn the system power back on and run the pump. Conrm that the light in the
Ozone window is ON.
FOR REPLACEMENT (System with AMP connector on the outside of the box)
1. Follow the above steps (1-4).
2. Uncover the controller box. Match the wires’ output of the ozone AMP
connector mark on the outside of the box with the AMP connector provided with
the ozone generator. Refer to Diagram 3.
3. Insert the wire. You will feel it “click” into position when it is seated. A slight tug
on the wire is all that’s needed to be sure that the terminal is seated.
4. Mate the AMP connector and power up
the spa. Make sure that you are in ltration
cycle and conrm that the light on the ozone
generator window is on.
Both diagrams, Diagrams 1 & 2,
show that the ozone generators
must be mounted with their inlets
facing down. As shown (right), the
chip generator outlet will be pointing
to the left once installed.
Diagram 1
Power Cords
Air Inlet
(near power cord)
CHP
Diagram 2
Water Level
in Hot Tub
Power Cords
Check Valve
Add tubing to create adequate Hartford Loop depending on spa configuration. *
* The Hartford Loop should extend as high as possible above the water level and as low as possible in the cabinet to avoid water intrusion into the ozone generator.
Water intrusion into the ozone generator is not covered under warranty.
Hartford Loop
Ozone Injector
Water
Flow
Supplied Tubing
a
i
r
f
l
o
w
W
a
t
e
r
F
l
o
w
Air Inlet