Installation Of A New Plug N’ Click Heater
– Turn off power to the system.
Using a Phillips screwdriver remove the
2 screws on top of the enclosure and open the cover.
Locate the 2 sensors holder on the circuit board.
Remove the 2 heater sensors by depressing the
clip and gently pulling on the wire to remove
each sensor cable.
Unplug the heater power connector by depressing
the holder clip to release the female connector.
Remove the 2 heater nuts with a 3/8” (9.5mm)
open wrench.
Remove heater from system.
PARTS AND TOOLS YOU NEED
– 3/8” (9.5mm) open end wrench
– 3/8” (9.5mm) nut driver
– Flat-head and Phillips screwdriver
– Replacement Balboa Heater
– Nyogel 760G (36308) and a stick
STEP 1 OPEN THE SYSTEM BOX
STEP 3 REMOVE THE 2 HEATER SENSORS
STEP 2 UNPLUG HEATER CONNECTOR
STEP 4 REMOVE NUTS ON HEATER
WARNING!
Please contact an electrician or your local electrical company when
connecting any spa electrical components. DO NOT OPEN THE SPA
SYSTEM AND ATTEMPT TO CONNECT THE CABLE CONNECTORS
YOURSELF. The high electrical voltage will harm or kill you.
Balboa Heater
Nyogel 760G (36308) and a stick
Vue de la page 0
1 2

Résumé du contenu

Page 1 - STEP 4 REMOVE NUTS ON HEATER

Installation Of A New Plug N’ Click Heater– Turn off power to the system.– Using a Phillips screwdriver remove the 2 screws on top of the enclosure

Page 2 - PLUG N’

REPLACEHEATER 06/25/2014©2014 Balboa Water Group. Single Source Solution. All rights reserved.1382 Bell Avenue | Tustin, CA 92780 | p 714.384.0